Product Data Sheet |
|
Product Description |
Kryptaglow®
Clear Protective Topcoat is a premium quality, industrial grade, high gloss,
alkyd enamel for moderate environments.
Designed for new construction and maintenance applications. It provides good gloss and color
retention, as well as outstanding durability. |
||||
|
Intended Uses |
Interior/Exterior,
all-purpose maintenance enamel for use on properly primed structural steel,
steel storage tanks, equipment, masonry and wood. Excellent maintenance product in the petroleum, food and
beverage, AG chem. And architectural commercial industries. These are typical uses and not
intended to limit the use of this product. Not intended for
use in continually wet areas. |
||||
|
Physical Properties |
Physical
Properties reported in this data sheet are for Clear Protective Topcoat. Information and data could vary
depending on base and color choice. |
||||
|
|
Color Finish/Sheen Resin
Type Clean-up
Solvent Solids
by Weight Solids
by Volume Dry
Film Thickness per Coat Wet
Film to Achieve DFT Theoretical
Coverage** Coverage
at DFT Drying
Time* (hours) [ASTM D 1640] At
70ºF (21ºC) VOC’s Thinning Service
Temperature Limit |
Clear 85+
@ 60º Alkyd Mineral
Spirits or Xylol 62% 42% 2
- 3 mils (50 - 75 microns) 4.5
– 7 mils (112.5 – 175 microns) 677
ft2/gallon @ 1 mil 225
– 338 ft2/gallon @ 2-3 mils DFT Touch
4 to 6 hours Recoat
8 hours Recoat
Max 30 days 3.75
lbs./gal. (450 grams/liter) DO
NOT THIN 200ºF
(93º C) |
|||
|
|
* Dry times may vary with surface
temperature, air movement, humidity and film thickness. ** Coverage rates are
estimates based on the products volume solids and make no allowance for
material loss during application.
Actual spread rates may vary dependent on applicator experience,
surface porosity and texture. |
||||
Surface Preparation Ferrous
Metal Surfaces Masonry
Surfaces: Poured Concrete Concrete Block Wood
Surfaces Previously
Painted Surfaces: Mildew: |
All
surfaces must be cured, clean, sound, dry and free of all dirt, dust,
efflorescence, wax, oil, grease, chalk, and any other contamination that
would interfere with new coating adhesion. Bare surfaces must be properly prepared and primed
prior to application of this product. An
abrasive blast to SSPC-SP-6 commercial blast is recommended. Blasted surfaces should be primed
before flash rusting occurs. If
blasting is not possible, remove loose rust and mill scale with hand or power
abrading tools per SSPC-SP-2 or SSPC-SP-3. New
concrete must cure for a minimum of 30 days at 72ºF (22ºC)
prior to coating application.
Level all surface projections and mortar spatters by stoning. Rake mortar joints clean and remove
all soluble salts. For a smooth
surface on interior or exterior porous block, use recommended fillers prior
to application of this product. Alkyd coatings are not recommended for
direct application to unprimed masonry surfaces. Sand
smooth any exposed wood surfaces.
Patch nail holes and any imperfections with wood filler or putty and
sand smooth. Remove sanding
dust. Solvent
wipe to remove surface contamination, then use an etching solution or abrade
the surface by sanding. Power
or hand washing is recommended to remove contamination. If oil or grease is present, use of a
cleaner/degreaser is required.
All cleaning residue must be completely rinsed from the surface. Allow to dry. Remove all loose coatings, rust and
corrosion by scraping, sanding or other abrading method as per SSPC-SP-2 and
SSPC-SP-3 or abrasive blast according to SSPC-SP-6 commercial blast. Use sandpaper to dull slick, glossy
and/or non-porous surfaces with sand paper. Spot prime bare areas or prime completely with appropriate
primer. Remove
by using a solution of one part household bleach and three parts water. Apply to mildewed area and
scrub. Allow solution to remain
on the surface for 3 to 5 minutes and then rinse completely and allow to dry
before coating application. |
||||
|
Application |
Stir
material prior to application.
Minimum surface and air temperature required for application is 40ºF (4ºC) and
at least 5ºF (3ºC) above the dew point. Curing is affected by temperature, humidity and air
movement. The minimums must be
maintained for at least eight (8) hours in order to achieve proper film
formation. Application at
elevated temperatures, wind conditions, and/or low humidity may require
special application procedures to achieve proper film formation. Finish coat should be applied at
1.5-2 mils DFT per coat. Brush
or Roller: A
good quality natural bristle brush will make application easier. Select a roller cover suited for the
texture of the surface to be coated.
Apply product in full even coats. Maintain a wet edge.
To insure adequate film build, two coats are recommended when applying
by brush or roller (See the drying times chart for recoat period). Allow the product to dry between
coats. Airless
Spray: Flush
airless lines with Xylol.
Equipment must be clean prior to start. Apply the product in even coats and maintain a wet edge. Use multiple passes to achieve film
build. Allow the product to dry
between coats. |
||||
|
|
Tip Orifice 0.013” to
0.015” |
Atomizing Pressure 2500-300 psi |
Mat’l Hose ID 1/4 “ |
Manifold Filter 60 mesh |
|
|
Safety Precautions |
Paint
products contain chemical ingredients which are considered hazardous. Prior to use, read container label
warnings and the current material Safety Data Sheet for important health and
safety information. Insure these
instructions are practiced during product application and cure. Keep out of reach of children. For
more detailed recommendations, please contact your local Kryptaglow
Representative |
||||
Co-Leash, Inc.
P.O. Box 272672
Tampa, FL 33688
(P) 813/920-1910 (F)
813/792-1418
www.kryptaglow.com