Product Data Sheet |
|
Product Description |
A
heavy duty two component, product formulated to provide resistance against a
wide range of solvents and chemicals under splash and spill conditions on a
variety of substrates.
Kryptaglow® can be applied to tightly adhered existing
coatings. Use for heavy duty
service on properly prepared masonry, drywall and structural steel surfaces. |
|
|
Intended Uses |
Designed
for heavy duty commercial and industrial maintenance on properly prepared
concrete block, poured concrete, structural steel, machinery and equipment,
tank exteriors and pipes. These
are typical uses and are not intended to limit the use of this product. |
|
|
Physical Properties |
Base
Cure Resin
Type Clean-up
Solvents Mixing
Ratio (by volume) Thinning Finish/Sheen Solids
by Weight Solids
by Volume Theoretical
Coverage ** Dry
Film Thickness/Coat Wet
Film to Achieve DFT Coverage
at DFT VOC’s Induction
Time Pot
Life Drying
Time * [At
70ºF(20ºC)][ASTM D 1650] Set
To Touch Dry
Through/Re-Coat |
Part
A Part
B 2
Component Heavy Duty Marine Coating MEK 1
Part Resin to 1 Part Cure Do
Not Thin 90+
@ 60º 71% 52% 834
ft2/gal @ 1 mil 2-3
mils (50-70 microns) 4-6
mils (100-150 microns) 278-417
ft2/gal 3.66
lb/gal (440 gm/liter) None 8-10
hours 10
minutes Minimum
Re-Coat Maximum
Re-Coat 4
hours 14 days |
|
|
*
Dry times vary with surface temperature, air movement, humidity and film
thickness. **
Coverage rates are estimates based on the products volume solids and make no
allowance for material loss during application. Actual spread rates may vary dependent on applicator
experience, surface porosity and texture. |
|
|
Recommended Primers |
Ferrous
Metal Galvanized
& Aluminum Metal Wood Drywall Plaster Interior
Concrete Block (Wet
Environment) Interior
Concrete Block (Dry
Environment) Exterior
Concrete Block Poured
Concrete |
Fast
Dry Alkyd Primer Self-priming Self-priming P.V.A.
Primer Alkyd
Enamel Undercoat Block
Filler Acrylic
Epoxy Block Filler Block
Filler Block
Filler Clear
Concrete Primer/Sealer |
Surface Preparation Masonry
Surfaces: Poured Concrete Concrete Block Ferrous
Metal Surfaces: New
Galvanized & Aluminum
Surfaces: Weathered
Galvanized &
Aluminum Surfaces: Wood
Surfaces: Plaster
Surfaces: Drywall
Surfaces: Previously
Painted Metal
Surfaces: Mildew: |
All
surfaces must be clean, sound, dry and free of all dirt, dust, wax, oil,
grease, chalk and any other contamination that would interfere with new
coating adhesion. Bare surfaces
must be properly prepared and primed prior to application of this
product. New
concrete must cure for a minimum of 30 days at 72ºF (22ºC) prior to
coating application. Level all
surface projections and mortar spatters by stoning. Rake mortar joints clean and remove all soluble
salts. Kryptaglow® is
self-priming on masonry surfaces, however, see “Recommended Primers,
Fillers and Sealers” for primer recommendations for interior and
exterior masonry surfaces in dry and wet areas. Abrasive
blast new steel to SSPC-SP-6.
Use proper abrasive to achieve an average of 1.5 to 2 mil
profile. Blasted surfaces should
be primed before flash rusting occurs.
If blasting is not practical, remove loose rust and mill scale with
hand or power abrading tools as per SSPC-SP-2 and SSPC-SP-3. Remove
surface contamination or passivators by scrubbing with a cleaning &
etching solution or blast per SSPC-SP-7 brush off blast. Power
or hand wash with detergent and rinse thoroughly. The surface must be dull and have a profile. Use a cleaning & Etching solution
if needed or blast per SSPC-SP-7 brush-off blast. Sand
smooth any exposed wood surfaces.
Patch nail holes and any imperfections with wood filler or putty and
sand smooth. Remove sanding
dust. New
plaster must cure for a minimum of 30 days at 72ºF (22ºC) prior to
coating application. Sand, fill
cracks with spackling compound, allow to dry and sand smooth. Remove dust. Fill
nail holes and imperfections with spackling compound and allow to dry. Sand tape joints and spackled areas
and remove dust. Power
or hand washing is recommended to remove contamination. If oil or grease is present, use of a
cleaner/degreaser is required.
All cleaning residue must be completely rinsed from the surface. Allow to dry. Remove all loose coatings, rust and
corrosion by scraping, sanding or other abrading method as per SSPC-SP-2 and
SSPC-SP-3, or abrasive blast as per SSPC-SP-6 commercial blast. Use sandpaper to dull slick, glossy
and/or non-porous surfaces with sandpaper. Remove
by using a solution of one part household bleach and three parts water. Apply to mildewed area and
scrub. Allow solution to remain
on the surface for 3 to 5 minutes and then rinse completely and allow to dry
before coating application. |
|||
|
Application Brush or Roller: Airless
Spray: |
Part
A (resin) and Part B (cure) are packaged in pre-measured kits. The mixing ratio is 1 part A to 1
part B. Stir both components
prior to intermixing. Thoroughly
mix Part B into Part A using an explosion-proof power drill and Jiffy mixer
to disperse pigments. The
material must be applied within the estimated pot life. For optimum application, air and
surface temperature should be from 50º to 90ºF (10º to
32ºC) and at least 5ºF (3ºC) above the dew point. Above 122ºF (50ºC), sagging
may occur. A minimum surface
temperature of 50ºF (10ºC) for eight hours after application is
recommended to achieve proper film formation. Apply
product in full even coats.
Maintain a wet edge. To
insure adequate film build, two coats are recommended when applying by brush
or roller (See the drying times chart for re-coat period). Allow the product to dry between
coats. A good quality bristle
brush will make application easier.
Select a roller cover suited for the texture of the surface to be
coated. Flush
airless lines with Gun Cleaner or MEK.
Equipment must be clean prior to start. Apply a wet coat in even, parallel passes with 50% overlap
to avoid bare areas and pinholes.
|
|||
|
|
Tip Orifice 0.017” to
0.012” |
Atomizing Pressure 2500 – 3000 PSI |
Mat’l Hose ID 1/4” to
3/8” |
Manifold Filter 60 mesh |
|
Safety Precautions |
Paint
products contain chemical ingredients, which are considered hazardous. Prior to use, read container label
warnings and the current Material Safety Data Sheet for important health and
safety information. Insure these
instructions are practiced during product application and cure. Keep out of reach of children. |
|||
Co-Leash, Inc.
P.O. Box 272672
Tampa, FL 33688
(P) 813/920-1910 (F)
813/792-1418
www.kryptaglow.com